MLBE MLD6500J-MLD12500J Open-Frame Diesel Generators

MLBE MLD6500J-MLD12500J Open-Frame Diesel Generators

  • Five models: MLD6500J, MLD7500J, MLD10000J, MLD11500J and MLD12500J
  • Published rated-output range: 5.0–10.0 kW across configurations
  • 12.5-litre fuel tank listed for each model
  • Single-phase AC specification and a separate listed 12 V / 8.3 A DC output
  • Confirm voltage, frequency, starting system, alternator and included equipment

Dealer and OEM orders: MOQ 50 units. OEM supply is supported. Send the required voltage, frequency, phase, model quantity and destination market.

Request a Quotation

Product details are pre-filled. Add your quantity and destination.

Choose a model for your quotation
Factory & OEM support

MOQ: 50 units. OEM supply is supported. Samples are chargeable.

  • OEM options: discuss branding, colours, labels and packaging for the agreed configuration.
  • New product development: share your application and market requirements for a feasibility and development-scope review.
  • Local marketing support: discuss product information, images and market-specific materials required for your launch.
  • Technical support: request model identification, applicable documents, service-parts information and support for the supplied configuration.

Availability, deliverables, timing and any charges are agreed in the quotation. See MLBE dealer and OEM supply.

Compare the diesel generator range before choosing a model.

MLD6500J–MLD12500J open-frame diesel generators: model-specific electrical data

Source: MLBE’s published model or series specification. Values are reference catalogue figures; a model-specific load-test report is needed to verify delivery performance.

Technical item MLBE published information
Model family Five J-series variants with published rated AC output spanning 5.0–10.0 kW
Fuel tank 12.5 L in the family comparison
Electrical configuration AC voltage, frequency, panel and socket schedule must match individual model
Engine and weight Model-specific engine and shipping-weight columns, not a single range-wide figure

Technical interpretation for dealer enquiries

The 12.5-litre tank figure is not a proven runtime; request fuel-consumption or running-time measurements at a stated fraction of rated electrical load. A J-series model cannot automatically take the larger H- or B-series tank or panel specification.

ISO 8528-1 covers generator rating classifications and ISO 8528-5:2025 provides generating-set performance criteria. ISO 8528-10 concerns noise measurement. These standards are given for technical context; no certification or test-result claim is made for this particular MLBE unit.

Compare MLBE diesel generator range; find the relevant user manual and generator maintenance guide. Send the intended load, market voltage, frequency, sockets, quantity and destination to MLBE technical sales.

MLD6500J–MLD12500J open-frame diesel generators

The MLBE J series comprises five models with published rated outputs from 5.0 to 10.0 kW across the listed configurations. Each model lists a 12.5-litre fuel tank. Compare the model-specific engine and weight information below, and confirm the electrical specification and runtime at the intended load.

Planning an MLD J-series dealer range

MLD6500J, MLD7500J, MLD10000J, MLD11500J and MLD12500J should be compared using complete electrical and service specifications. Match each stock model to a defined customer load requirement and keep panel and accessory details with the order record.

Configuration checklist

  • List the equipment that must run together and identify motor or compressor starting demand.
  • Specify voltage, frequency, phase, sockets and the required starting system; separate standard equipment from options.
  • Include transport accessories, battery where applicable and the required model-specific service-parts package in the written order.

What information makes a generator comparison meaningful?

Use rated output, voltage, frequency, phase, starting system, operating conditions and included equipment together. A comparison based only on maximum output can overlook the configuration needed by the actual load.

Operation and service planning

Operate portable combustion generators outdoors, away from doors, windows and vents, with exhaust directed away from occupied areas. Never connect a generator to a building through a wall socket. A building connection requires a qualified electrician and suitable transfer equipment. Stop and cool the engine before refuelling.

For this J-series range, state the complete model from MLD6500J to MLD12500J and the engine identification. Include the single-phase AC configuration, panel photograph and any fitted 12 V DC connection. Request the corresponding wiring and parts references for the model with the listed 12.5-litre tank. Contact MLBE technical support with these details. The MLBE document centre helps identify the relevant resources. Confirm document revision, included accessories, packaging and agreed support terms for the supplied configuration.

Compare MLD6500H-MLD12500H and MLD6500B-MLD12500B for related MLBE options. For factory orders, provide quantities, destination, configuration and artwork requirements through MLBE dealer and OEM supply.

MLD6500J–MLD12500J: fuel and configuration questions

Does the J-series fuel-tank figure establish runtime?

The table lists a 12.5 L fuel tank, but does not provide a runtime figure. Ask for fuel-consumption or runtime data at a stated load for the exact J-series model.

What should I verify before confirming a J-series order?

Request the missing voltage, frequency, panel and alternator details, together with the starting system and supplied accessories. Confirm these against the model and output required for the destination market.

For order preparation, see the generator supplier checklist. Browse the diesel generator range, or request model-specific documents through MLBE technical support.

Technical specifications

Model MLD6500J MLD7500J MLD10000J MLD11500J MLD12500J
Voltage (V) Confirm for the selected configuration
Frequency (Hz) Confirm for the selected configuration
Maximum AC output (kW) 5.5/6.0 6.5/7.0 7.3/7.8 8.0/8.5 10.0/11.0
Rated AC output (kW) 5.0/5.5 6/6.5 6.8/7.3 7.5/8.0 9.2/10.0
Power Factor 1 1 1 1 1
DC output 12V/8.3A 12V/8.3A 12V/8.3A 12V/8.3A 12V/8.3A
Phase Single phase Single phase Single phase Single phase Single phase
Panel Detail Confirm for the selected configuration
Engine MLD186FA, /418cc MLD188F MLD192FA, /498cc MLD195FAE/532cc MLD1100FE/667cc
Alternator Confirm for the selected configuration
Fuel Tank Capacity 12.5 L 12.5 L 12.5 L 12.5 L 12.5 L
Net weight (kg) 116 116 122 123 142
Gross weight (kg) 120 120 125 126 145
Packing Size(L×W×H) 768*428*655 768*428*655 768*428*655 768*428*655 825*615*865
Brand

MLBE

Product Range

Generators

Fuel Type

Diesel