MLD6500J–MLD12500J open-frame diesel generators: model-specific electrical data
Source: MLBE’s published model or series specification. Values are reference catalogue figures; a model-specific load-test report is needed to verify delivery performance.
| Technical item | MLBE published information |
|---|---|
| Model family | Five J-series variants with published rated AC output spanning 5.0–10.0 kW |
| Fuel tank | 12.5 L in the family comparison |
| Electrical configuration | AC voltage, frequency, panel and socket schedule must match individual model |
| Engine and weight | Model-specific engine and shipping-weight columns, not a single range-wide figure |
Technical interpretation for dealer enquiries
The 12.5-litre tank figure is not a proven runtime; request fuel-consumption or running-time measurements at a stated fraction of rated electrical load. A J-series model cannot automatically take the larger H- or B-series tank or panel specification.
ISO 8528-1 covers generator rating classifications and ISO 8528-5:2025 provides generating-set performance criteria. ISO 8528-10 concerns noise measurement. These standards are given for technical context; no certification or test-result claim is made for this particular MLBE unit.
Compare MLBE diesel generator range; find the relevant user manual and generator maintenance guide. Send the intended load, market voltage, frequency, sockets, quantity and destination to MLBE technical sales.
MLD6500J–MLD12500J open-frame diesel generators
The MLBE J series comprises five models with published rated outputs from 5.0 to 10.0 kW across the listed configurations. Each model lists a 12.5-litre fuel tank. Compare the model-specific engine and weight information below, and confirm the electrical specification and runtime at the intended load.
Planning an MLD J-series dealer range
MLD6500J, MLD7500J, MLD10000J, MLD11500J and MLD12500J should be compared using complete electrical and service specifications. Match each stock model to a defined customer load requirement and keep panel and accessory details with the order record.
Configuration checklist
- List the equipment that must run together and identify motor or compressor starting demand.
- Specify voltage, frequency, phase, sockets and the required starting system; separate standard equipment from options.
- Include transport accessories, battery where applicable and the required model-specific service-parts package in the written order.
What information makes a generator comparison meaningful?
Use rated output, voltage, frequency, phase, starting system, operating conditions and included equipment together. A comparison based only on maximum output can overlook the configuration needed by the actual load.
Operation and service planning
Operate portable combustion generators outdoors, away from doors, windows and vents, with exhaust directed away from occupied areas. Never connect a generator to a building through a wall socket. A building connection requires a qualified electrician and suitable transfer equipment. Stop and cool the engine before refuelling.
For this J-series range, state the complete model from MLD6500J to MLD12500J and the engine identification. Include the single-phase AC configuration, panel photograph and any fitted 12 V DC connection. Request the corresponding wiring and parts references for the model with the listed 12.5-litre tank. Contact MLBE technical support with these details. The MLBE document centre helps identify the relevant resources. Confirm document revision, included accessories, packaging and agreed support terms for the supplied configuration.
Compare MLD6500H-MLD12500H and MLD6500B-MLD12500B for related MLBE options. For factory orders, provide quantities, destination, configuration and artwork requirements through MLBE dealer and OEM supply.
MLD6500J–MLD12500J: fuel and configuration questions
Does the J-series fuel-tank figure establish runtime?
The table lists a 12.5 L fuel tank, but does not provide a runtime figure. Ask for fuel-consumption or runtime data at a stated load for the exact J-series model.
What should I verify before confirming a J-series order?
Request the missing voltage, frequency, panel and alternator details, together with the starting system and supplied accessories. Confirm these against the model and output required for the destination market.
For order preparation, see the generator supplier checklist. Browse the diesel generator range, or request model-specific documents through MLBE technical support.
Technical specifications
| Model | MLD6500J | MLD7500J | MLD10000J | MLD11500J | MLD12500J |
| Voltage (V) | Confirm for the selected configuration | ||||
| Frequency (Hz) | Confirm for the selected configuration | ||||
| Maximum AC output (kW) | 5.5/6.0 | 6.5/7.0 | 7.3/7.8 | 8.0/8.5 | 10.0/11.0 |
| Rated AC output (kW) | 5.0/5.5 | 6/6.5 | 6.8/7.3 | 7.5/8.0 | 9.2/10.0 |
| Power Factor | 1 | 1 | 1 | 1 | 1 |
| DC output | 12V/8.3A | 12V/8.3A | 12V/8.3A | 12V/8.3A | 12V/8.3A |
| Phase | Single phase | Single phase | Single phase | Single phase | Single phase |
| Panel Detail | Confirm for the selected configuration | ||||
| Engine | MLD186FA, /418cc | MLD188F | MLD192FA, /498cc | MLD195FAE/532cc | MLD1100FE/667cc |
| Alternator | Confirm for the selected configuration | ||||
| Fuel Tank Capacity | 12.5 L | 12.5 L | 12.5 L | 12.5 L | 12.5 L |
| Net weight (kg) | 116 | 116 | 122 | 123 | 142 |
|---|---|---|---|---|---|
| Gross weight (kg) | 120 | 120 | 125 | 126 | 145 |
| Packing Size(L×W×H) | 768*428*655 | 768*428*655 | 768*428*655 | 768*428*655 | 825*615*865 |